Sniffer4D Nano 2 Plus & AIRINS.ai - Quick Start Guide

Document version:

1.Sniffer4D Nano 2 Plus Packing List

Illustration from the source document
Illustration from the source document

2.Packing Lists of Integration Kits (Sold Separately)

2.1Matrice 4E / 4T Integration Kit

  • Sniffer4D Nano 2 Plus Multi-Gas System
Illustration from the source document
  • Sniffer4D Nano 2 Plus Methane System
Illustration from the source document

2.2Matrice 400 Integration Kit

  • Sniffer4D Nano 2 Plus Multi-Gas System
Illustration from the source document
  • Sniffer4D Nano 2 Plus Methane System
Illustration from the source document

2.3Vehicle Integration Kit

* Coming soon

2.4Go 2 Robot Dog Integration Kit

* Coming soon

3.Sniffer4D Nano 2 Plus Main Components & Status LEDs

3.1Main Components

Figure from the source document

3.2Status LEDs

Figure from the source document
Figure from the source document

4.Integrating Sniffer4D Nano 2 Plus with UAVs

4.1Integration with DJI Matrice 4D / 4TD inside DJI Dock 3

1. Open the E-Port waterproof rubber cover on the DJI Dock 3's Matrice 4D / 4TD, align the PSDK Port on the bottom of the Sniffer4D Nano 2 Plus with the E-Port on top of the UAV, and insert it vertically, carefully and fully.

Figure from the source document

2. Using a hex key, fasten the front of the Sniffer4D Nano 2 Plus with two M3 × 25 mm (longer) screws, and secure the rear with two M3 × 20 mm (shorter) screws.

Figure from the source document

3. Log in to DJI FlightHub 2 and verify that the Sniffer4D Nano 2 Plus is operating normally via Virtual Cockpit or Dock Live View.

Figure from the source document

4.2Integration with DJI Matrice 4E / 4T

4.2.1Sniffer4D Nano 2 Plus Multi-Gas Version without Extended Sampling Tube

1. Align the two mounting holes at the bottom of the Sniffer4D Nano 2 Plus Matrice 4E / 4T mounting bracket with the screw holes on top of the UAV. Using a hex key, secure the bracket with two M3 × 6 mm hex screws.

Figure from the source document

2. Open the UAV E-Port interface, then insert the adapter cable in the direction shown and ensure it is securely connected. Align the Sniffer4D Nano 2 Plus with the connector on the other end of the adapter cable, and press it down vertically and steadily until the device is fully seated and secured in place.

Figure from the source document

3. Use a hex key to tighten four M3 × 22 mm screws to secure the Sniffer4D Nano 2 Plus to the bracket and complete the installation.

Figure from the source document

4. Power on the UAV. Use DJI Pilot 2 to view the real-time data of the Sniffer4D Nano 2 Plus and confirm that the device is operating normally.

Figure from the source document

4.2.2Sniffer4D Nano 2 Plus Methane-Only Version with Extended Sampling Tube

1. Connect the extended sampling tube to the corresponding interface on the Sniffer4D Nano 2 Plus Matrice 4E / 4T bracket. Tighten two M2.5 screws to ensure the sampling tube is securely fixed with no looseness.

Figure from the source document

2. Align the two screw holes at the bottom of the Sniffer4D Nano 2 Plus Matrice 4E / 4T bracket with the screw holes on the top of the UAV body. Use a hex key to tighten two M3 × 6 mm hex screws to secure the bracket.

Figure from the source document

3. Open the UAV E-Port interface, insert the adapter cable in the direction shown, and ensure it is properly connected. Then align the PSDK port on the bottom of the Sniffer4D Nano 2 Plus with the connector at the other end of the adapter cable, and press it down vertically and steadily until the device is fully seated and secured in place.

Figure from the source document

4. Use a hex key to tighten four M3 × 22 mm screws to secure the Sniffer4D Nano 2 Plus to the bracket.

Figure from the source document

5. Insert the extended sampling tube into the quick connector until it is locked in place with no looseness. Then screw the gas tube quick connector clockwise into the air inlet of the main unit and tighten it to ensure proper sealing. This completes the installation.

Figure from the source document

6. Power on the UAV. Use DJI Pilot 2 to view the real-time data of the Sniffer4D Nano 2 Plus and confirm that the device is operating normally.

Figure from the source document

4.3Integration with DJI Matrice 400

4.3.1Sniffer4D Nano 2 Plus Multi-Gas Version without Extended Sampling Tube

1. Align the four screw holes at the bottom of the Sniffer4D Nano 2 Plus Matrice 400 bracket with the screw holes on the main unit. Press down vertically until it is properly seated, then insert the adapter cable connector into the corresponding interface on the bracket and ensure it is securely connected.

Figure from the source document

2. Use a hex key to tighten four M3 × 20 mm screws to secure the Sniffer4D Nano 2 Plus to the bracket.

Figure from the source document

3. Remove the protective cover from the adapter ring of the Sniffer4D Nano 2 Plus Matrice 400 bracket.

Figure from the source document

4. Align the white mark on the adapter ring of the Sniffer4D Nano 2 Plus Matrice 400 bracket with the red mark on the UAV gimbal interface. Insert it and rotate until the red marks are aligned to complete the installation.

Figure from the source document

5. Power on the UAV. Use DJI Pilot 2 to view the real-time data of the Sniffer4D Nano 2 Plus and confirm that the device is operating normally.

Figure from the source document

4.3.2Sniffer4D Nano 2 Plus Methane-Only Version with Extended Sampling Tube

1. Connect the extended sampling tube to the corresponding interface on the Sniffer4D Nano 2 Plus Matrice 400 bracket. Tighten two M2.5 thumb screws to ensure the sampling tube is securely fixed with no looseness.

Figure from the source document

2. Align the four screw holes at the bottom of the Sniffer4D Nano 2 Plus Matrice 400 bracket with the screw holes on the main unit. Press down vertically until it is properly seated, then insert the adapter cable connector into the corresponding interface on the bracket and ensure it is securely connected.

Figure from the source document

3. Use a hex key to tighten four M3 × 20 mm screws to secure the Sniffer4D Nano 2 Plus to the bracket.

Figure from the source document

4. Insert the extended sampling tube into the quick connector until it is locked in place with no looseness. Then screw the gas tube quick connector clockwise into the air inlet of the main unit and tighten it to ensure proper sealing.

Figure from the source document

5. Remove the protective cover from the adapter ring of the Sniffer4D Nano 2 Plus Matrice 400 bracket.

Figure from the source document

6. Align the white mark on the adapter ring of the Sniffer4D Nano 2 Plus Matrice 400 bracket with the red mark on the UAV gimbal interface. Insert it and rotate until the red marks are aligned to complete the installation.

Figure from the source document

7. Power on the UAV. Use DJI Pilot 2 to view the real-time data of the Sniffer4D Nano 2 Plus and confirm that the device is operating normally.

Figure from the source document

4.4Integration with DJI Matrice 30 / 30T

* Coming soon

5.Getting Started with AIRINS.ai Software

5.1Register an account on AIRINS.ai (If you already have an AIRINS.ai account, you may skip this section 5.1)

1. Open your browser and navigate to the AIRINS.ai website: https://airins.ai.

2. On the Log In / Sign Up page, enter a valid email address and click "Log In / Sign Up".

3. Enter a valid invitation code and click "Submit". (If you do not have an invitation code, please contact your assigned AIRINS sales engineer to obtain one. Each invitation code is single-use only.)

4. Check your email inbox (including the spam / junk folder) for the 6-digit verification code, then enter it on the page. If the code does not arrive after a long time, click "Resend Verification Code" or check your spam folder.

5. Set a login password (recommended: at least 8 characters, including letters and numbers).

6. Fill in your basic information (full name and organization / company name), then click "Submit".

You can now log in to AIRINS.ai using your email and password.

Figure from the source document

5.2Bind Your Sniffer4D Nano 2 Plus to Your AIRINS.ai Account

1. Log in to the AIRINS.ai web portal using your registered email and password.

2. On the homepage, click the "Bind Device" button.

3. In the input fields, enter the device’s serial number (found on the label on the side of the device) and assign a device nickname.

4. Click "Confirm Binding". Once the system verifies the information, the binding is complete.

Figure from the source document

5.3AIRINS.ai Detailed Tutorial

For more in-depth guidance and learning resources, please click the link below to access the detailed & interactive tutorial page.

AIRINS.ai Detailed Tutorial

6. Executing a Typical Monitoring Mission

6.1Executing a Typical Automated Waypoint Monitoring Mission Using DJI Dock 3 & DJI FlightHub 2

1. Follow the installation steps in Section 4.1 of this guide to install the Sniffer4D Nano 2 Plus onto the DJI Matrice 4D / 4TD aircraft in DJI Dock 3.

Figure from the source document

2. Based on the flight route planned by DJI FlightHub 2 and the area where automated operations are required, configure the mission start zone and mission end zones in AIRINS.ai. The Sniffer4D Nano 2 Plus will then: (1) automatically start mission recording, and (2) automatically stop mission recording based on these settings.

As illustrated below, when the Sniffer4D Nano 2 Plus is not recording and passes through the blue circle (start mission zone), it will automatically start recording. When a mission is in progress and the device passes through the red circle (end mission zone), it will automatically stop recording.

Figure from the source document

3. Start the automated flight route in DJI FlightHub 2.

Figure from the source document

4. During the mission, real-time monitoring data from the Sniffer4D Nano 2 Plus can be viewed in the Virtual Cockpit on DJI FlightHub 2 via the PSDK widget panel. You may also view the real-time mission status on AIRINS.ai (Sniffer4D is required to have Internet access over 4G).

Figure from the source document

5. After the mission is complete, historical missions can be reviewed on AIRINS.ai at any time. The default naming format for historical missions is: "Serial Number_Mission Start Date_Mission Start Time".

Figure from the source document

6.2Executing a Typical Manual Flight Monitoring Mission

1. Following the installation steps in Section 4.2 of this guide, install the Sniffer4D Nano 2 Plus onto the UAV and complete the pre-flight checks.

Figure from the source document

2. Open DJI Pilot 2, navigate to the flight interface, and tap the PSDK widget panel to view device information and confirm the device is operating normally.

Figure from the source document

3. Tap the mission recording icon in the PSDK widget to start recording the mission. (The icon background will then turn yellow and the panel will then display "Mission in Progress".) Maneuver the UAV to make full contact with the gas plume in the target area to collect georeferenced concentration data.

Figure from the source document

4. During the mission, real-time monitoring data can be viewed via the PSDK widget panel at any time. You may also view the real-time mission status on AIRINS.ai (Sniffer4D is required to have Internet access over 4G).

Figure from the source document

5. Once the operation is complete, tap the mission icon in the PSDK widget to stop recording the mission. (The icon background will then turn grey and "Mission in Progress" will then no longer be displayed on the panel.)

Figure from the source document

6. After the mission is complete, historical missions can be reviewed on AIRINS.ai at any time. The default naming format for historical missions is: "Serial Number_Mission Start Date_Mission Start Time".

Figure from the source document

6.3Executing a Typical Vehicle-Based Monitoring Mission

* Coming soon

7.Sniffer4D Nano 2 Plus Local Firmware Upgrade & Calibration

7.1Firmware Upgrade

1. Go to the AAI Real-Time Panel and click the Firmware Management icon to check whether a newer firmware version is available for your Sniffer4D Nano 2 Plus. This page only displays the latest firmware version.

Illustration from the source document

2. If a newer firmware version is available, click Download and save the firmware package to your local computer.

Illustration from the source document

3. After extracting the downloaded firmware file (.zip), you will see three firmware files (.zip) for different versions of Sniffer4D Nano 2 Plus:

  • Multi-Gas version,
  • Methane-Only version,
  • TSP-Only version.

Select the firmware file that matches your device version and extract it again. The extracted nano2+.bin file is the firmware file used for the device upgrade.

Illustration from the source document

4. Ensure your Sniffer4D Nano 2 Plus is powered off, then remove the SD card from the device.

Illustration from the source document

5. Use a card reader to connect the SD card to your computer. Open the corresponding SD card drive and copy the downloaded firmware file to the 'Upgrade' folder on the SD card. If the folder does not exist, create a new folder named 'Upgrade'.

Illustration from the source document

6. After the firmware file has been copied, safely eject the SD card from the computer and insert it back into the Sniffer4D Nano 2 Plus.

Illustration from the source document

7. Power on the Sniffer4D Nano 2 Plus. The device will automatically detect the firmware file and start the upgrade process. The upgrade takes approximately 5 minutes. During this process, the status LEDs will blink in sequence (except for the 4G LED). Do not power off the device or remove the SD card during this period.

Illustration from the source document

8. When the device's status LEDs return to its normal status, manually restart the Sniffer4D Nano 2 Plus. After the restart is complete, the firmware upgrade is finished.

Illustration from the source document

7.2Calibration Principles

  • Under ideal conditions, the measured values are consistent with the actual concentrations, as shown in the diagram below.
Figure from the source document
  • In practice, however, due to limitations in monitoring methods, significant differences in local environmental parameters (such as temperature, humidity, and atmospheric pressure), and inconsistent standards across regions, the measured concentrations may not match the actual concentrations — though a certain correlation (trend alignment) exists. An example is shown below.
Figure from the source document
  • Calibration is the process of applying calibration parameters to the measured concentrations so that the calibrated values more closely match the actual concentrations, as shown below.
Figure from the source document
  • In the Sniffer4D Nano 2 Plus, the calibration formula is as follows:
    • (Raw Value + Zero-Point Offset) × Sensitivity Calibration Factor = Calibrated Value
    • The Sensitivity Calibration Factor and Zero-Point Offset are the two calibration parameters, defined as follows:
      • Sensitivity Calibration Factor: The slope of the line in Diagram 2 divided by the slope of the line in Diagram 1. Default value: 1.
      • Zero-Point Offset: When the Sensitivity Calibration Factor is at its default value and the actual concentration is 0, this is the negative of the measured concentration value. Default value: 0.
    • Prior to shipment, AIRINS performs rigorous precision calibration on specific monitoring modules (using the long-term data comparison method — see the calibration report) and writes the corresponding calibration parameters to the device. Due to significant environmental differences across regions, inconsistent standards, and device aging, some measurement deviation may occur over time. If this happens, you may carefully adjust the calibration parameters yourself.

7.3Rough Calibration

  • Rough Calibration for Light-Scattering (Particulate Matter) Monitoring Modules
    • For light-scattering monitoring modules (such as the PM particulate matter module), rough calibration assumes that the Zero-Point Offset does not require adjustment — only the Sensitivity Calibration Factor needs to be calibrated. This method is simple, fast, and yields good marginal results.
    • Steps:

      1. Place the device near the monitoring point of a reference instrument (e.g. a national standard monitoring station or another instrument with reliable data), at the same height as the reference instrument where possible, and power on the device.

      2. Connect the device to AIRINS.ai, and navigate to the calibration interface. Select the light-scattering monitoring module you wish to calibrate (e.g. PM particulate matter, TSP), and tap the module to enter the module calibration page.

      Figure from the source document

      3. Calculate the new Sensitivity Calibration Factor using the formula shown below.

      Figure from the source document

      4. Using the reference instrument, obtain the corresponding monitoring value and apply the formula to calculate the new Sensitivity Calibration Factor. Enter the new value into the Sensitivity Calibration Factor input field in the module calibration interface, then tap "Upload".

      • The "Current Sensitivity Calibration Factor" refers to the value currently shown in the interface. For example, in the sample screenshot, the Sensitivity Calibration Factor for PM₂.₅ is 1.
      • This value is for illustration purposes only and should not be used as a reference for calibrating your Sniffer4D Nano 2 Plus.
      Figure from the source document
  • Rough Calibration for Non-Light-Scattering Monitoring Modules
    • For non-light-scattering monitoring modules, rough calibration assumes that the Sensitivity Calibration Factor does not require adjustment — only the Zero-Point Offset needs to be calibrated. This method is simple and fast.
    • Steps:

      1. For steps on connecting to the device and navigating to the calibration interface, refer to the rough calibration steps for light-scattering (particulate matter) monitoring modules above.

      2. In the device module details, select the non-light-scattering monitoring module you wish to calibrate (e.g. CO, SO₂, NO₂, TVOC, O₃+NO₂, H₂S, NH₃, HCHO, etc.), and tap Calibration Parameter Settings to enter the module calibration interface.

      Figure from the source document

      3. Calculate the new Zero-Point Offset using the formula shown below.

      Figure from the source document

      4. Using the reference instrument, obtain the corresponding monitoring value and apply the formula to calculate the new Zero-Point Offset. Enter the new value into the Zero-Point Offset input field in the module calibration interface, then tap "Upload".

      • The "Current Zero-Point Offset" refers to the value currently shown in the interface. For example, in the sample screenshot, the current Zero-Point Offset is 0.000. (This value is for illustration purposes only and should not be used as a reference for calibrating your Sniffer4D Nano 2 Plus.)
      Figure from the source document

7.4Precision Calibration (For Advanced Users Only)

  • Calibration Chamber Main Components
    Figure from the source document
  • Procedure
    • Using clean air and at least one gas of known concentration (two-or-multi-point calibration), this method determines the Sensitivity Calibration Factor and Zero-Point Offset of the monitoring module. This calibration method offers higher accuracy (assuming the reference gas is of good quality).
    • Before calibration, prepare the following: clean air, a gas cylinder containing the target gas at least a known concentration, tubing, a flow meter, the Sniffer4D Nano 2 Plus calibration chamber, and a power supply for the Sniffer4D Nano 2 Plus. Connect to the Sniffer4D Nano 2 Plus via network communication.
    • Steps:

      1. As illustrated, place the Sniffer4D Nano 2 Plus into the sealed chamber. Connect the USB-C power cable and confirm the device has started up normally, then tighten the surrounding fastening screws.

      Figure from the source document

      2. Connect the Sniffer4D Nano 2 Plus to the reference gas cylinder using tubing. Before calibration, verify that the entire gas circuit is airtight. If the gas cylinder does not have flow control, add a flow meter to the gas circuit. As network communication is used for parameter adjustment, ensure the Sniffer4D Nano 2 Plus is placed in an area with a strong network signal. (See diagram below for reference gas calibration setup.)

      Figure from the source document

      3. Open AIRINS.ai and log in. Navigate to More Details and turn off the Active Air Intake switch (this disables the intake fan at the rear of the Sniffer4D Nano 2 Plus). On the More Details page, select the monitoring module you wish to calibrate, and tap Calibration Parameter Settings to enter the module calibration interface.

      Figure from the source document

      4. Continuously inject clean air into the calibration chamber at a flow rate of 1–3 L / min. A flow meter can be used for precise control.

      5. Once the readings have stabilized and are no longer decreasing (typically 1–10 minutes depending on conditions), calculate the new Zero-Point Offset:

      • New Zero-Point Offset = Current Zero-Point Offset − Current device concentration reading.
      • The "Current Zero-Point Offset" refers to the value currently shown in the interface.

      6. Enter the new Zero-Point Offset into the Zero-Point Offset input field in the module calibration interface, then tap "Upload". (This value is for illustration purposes only and should not be used as a reference for calibrating your Sniffer4D Nano 2 Plus.)

      Figure from the source document

      7. Continuously inject the target gas at a known concentration into the calibration chamber at a flow rate of 1–3 L / min.

      Figure from the source document

      8. Once the readings have stabilized and are no longer increasing (typically 1–10 minutes depending on conditions), calculate the new Sensitivity Calibration Factor using the formula shown below.

      Figure from the source document

      The "Current Sensitivity Calibration Factor" refers to the value currently shown in the interface. For example, in the sample screenshot, the current Sensitivity Calibration Factor is 1.5392.

      9. Enter the new Sensitivity Calibration Factor into the Sensitivity Calibration Factor input field in the module calibration interface, then tap "Upload". (This value is for illustration purposes only and should not be used as a reference for calibrating your Sniffer4D Nano 2 Plus.)

      Figure from the source document

7.5Configuring the TVOC Module for a Specific VOC Target Gas

Figure from the source document

8.Common Operation Errors, Troubleshooting & Product Limitations

8.1Common Operation Errors

  • When installing the Sniffer4D Nano 2 Plus onto the Matrice 4D / 4TD, using incorrect screw specifications (e.g. installing the front and rear screws in reverse, resulting in the device not being securely fastened) may cause the device to lose communication with the UAV, or result in unstable communication.
  • If the Sniffer4D Nano 2 Plus is not given a sufficient temperature-stabilizing time of 3–10 minutes before operation, the monitoring mission data may contain systematic errors (e.g. readings that continuously drift upward or downward).
  • When running an automated monitoring mission, if the mission start and end recording zones are not correctly configured in AIRINS.ai, or if the start and end mission actions are not set during waypoint mission planning, no mission data will be recorded.
  • When powered by a supply that does not meet 5 V / 3 A (15 W), the Sniffer4D Nano 2 Plus may fail to start up fully or produce data with significant errors. Using the official AIRINS integration kits and AIRINS-recommended carrying platforms will minimize the likelihood of this issue.

8.2Common Troubleshooting

  • If the Sniffer4D Nano 2 Plus widget icon in DJI Pilot 2 fails to load correctly, this is typically caused by an incorrect startup sequence between the UAV and the remote controller. Fully closing and relaunching DJI Pilot 2 app should resolve the issue.
  • You can enter the Sniffer4D Nano 2 Plus Diagnostic Mode for more information. When contacting after-sales support, proactively provide the content displayed (see illustration below) in the DJI Pilot 2 floating window under this mode for more efficient assistance.
Figure from the source document
  • Measurement Noise Test for Sniffer4D Nano 2 Plus (Methane-Only Version): After the device is started and fully warmed up in a clean and stable environment, the CH4 concentration readings should show only slight fluctuations, approximately ±0.1 ppm, as shown in Figure 1. If the CH4 concentration readings fluctuate significantly, at ±0.5 ppm or higher, as shown in Figure 2, and do not return to normal after the device has been left running for 5 minutes, the methane measurement optical chamber is likely contaminated and the device should be returned to the factory for deep cleaning.
Figure from the source document

Figure 1 - Normal

Figure from the source document

Figure 2 - Abnormal

8.3Product Limitations

  • Temperature drift in gas parameter readings: Some gas sensors in the Sniffer4D Nano 2 Plus operate on electrochemical principles and are susceptible to zero-point shifts caused by temperature changes. This drift (sometimes referred to as "dropping down to zero") is especially noticeable when monitoring in low-concentration scenarios (e.g. ambient air monitoring). Where possible, ensure the device operates in a stable ambient temperature environment.
  • Not recommended for use in rain or high-humidity conditions: While the Sniffer4D Nano 2 Plus is water-resistant and will not be damaged by rain, sensor accuracy may be affected by ambient moisture in the environment.
  • Power input: The Sniffer4D Nano 2 Plus supports direct connection to the DJI Matrice 4D / 4TD E-Port. It also supports power via a USB-A to USB-C cable, but does not support USB-C to USB-C cables. When using a USB-A to USB-C cable, the power supply must meet a DC 5–24 V / 3 A, otherwise Sniffer4D may not operate properly.
  • Particulate matter readings may be affected by carrying platform movement: The particulate matter sensor in the Sniffer4D Nano 2 Plus uses diffusion-based air intake and cannot achieve fully isokinetic sampling. While the Sniffer4D Nano 2 Plus's specialized particulate matter intake design compensates for most motion-induced effects, it cannot eliminate them entirely. During sudden acceleration, braking, sharp turns, or high-speed movement exceeding 10 m/s, particulate matter readings may exhibit brief minor fluctuations of 5–10 µg/m³. We strongly recommend keeping platform movement smooth during operation, with a speed not exceeding 8 m/s.
  • Gas parameter readings may be affected by carrying platform movement: The baseline (zero point) of gas parameter sensors in the Sniffer4D Nano 2 Plus (such as electrochemical and MP-TDLAS sensors) is sensitive to atmospheric pressure changes. While the Sniffer4D Nano 2 Plus's specialized intake design mitigates some pressure effects caused by movement, it cannot eliminate them entirely. During sudden acceleration, braking, sharp turns, or high-speed movement especially exceeding 10 m/s, significant pressure changes around the device may cause brief fluctuations in gas parameter readings. We strongly recommend keeping platform movement smooth during operation, with a speed not exceeding 8 m/s.